SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and
servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could
result in death or serious injury. When working on the equipment, observe all precautions in the literature
and on the tags, stickers, and labels that are attached to the equipment.
February 2013 VRF-SVX30A-EN
Installation, Operation,
and Maintenance
Variable Refrigerant Flow System
High-Wall Indoor Unit Series
Models: 4TVW0007B100NB, 4TVW0009B100NB, 4TVW0012B100NB,
4TVW0018B100NB, 4TVW0020B100NB, 4TVW0024B100NB
Przeglądanie stron 0
1 2 3 4 5 6 ... 36 37

Podsumowanie treści

Strona 1 - Installation, Operation

SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

Strona 2 - Introduction

10 VRF-SVX30A-ENInstallationInstalling Refrigerant PipingConnect field-supplied piping using flared connections (not supplied) or by brazing. The lar

Strona 3 - Table of Contents

VRF-SVX30A-EN 11Installation3. Attach the yoke to the flaring bar, centering the conical part over the end of the pipe that is extending above the fla

Strona 4 - . . . 35

12 VRF-SVX30A-ENInstallationLeak Testing Pipe Connections Notes:• All required piping pressure tests must be completed in accordance with national an

Strona 5 - Model Number Description

VRF-SVX30A-EN 13InstallationInstalling the Drain SystemFollow these precautions and recommendations when installing the drain hose to the indoor unit:

Strona 6 - Preparing for Installation

14 VRF-SVX30A-ENInstallation5. Pass the drain hose under the refrigerant pipe and through the hole in the wall. Keep the hose tight and make sure it

Strona 7 - Service Clearances

VRF-SVX30A-EN 15InsulationInsulationAfter determining that there are no leaks in the refrigerant pipes or drainage hose, insulate them as described in

Strona 8

16 VRF-SVX30A-ENWiring the UnitWiring the UnitObserve the following precautions when making electrical connections. • Make all electrical connections

Strona 9 - Purging the Unit

VRF-SVX30A-EN 17Wiring the UnitFigure 1. Wiring diagram1(L)2(N) F2F1 1(L)1(L)2(N)2(N)F1F1F2F2F4F3F3 F4208–230 VF1F2NLNLNLNLF1F2F1F1F1F2F2 F21(L)2(N)

Strona 10 - Installing Refrigerant Piping

18 VRF-SVX30A-ENConfigurationConfigurationAll VRF indoor units are factory configured. If modifications are required, one of the following control de

Strona 11 - Installation

VRF-SVX30A-EN 19ConfigurationFigure 2. VRF Wireless Remote ControlMode buttonFan upTemp upTemp downFan downPower button2-digit segment

Strona 12 - Leak Testing Pipe Connections

© 2013 Trane All rights reserved VRF-SVX30A-ENIntroductionRead this manual thoroughly before operating or servicing this unit.Warnings, Cautions, a

Strona 13 - Installing the Drain System

20 VRF-SVX30A-ENConfigurationThe 2-Digit SegmentsEach 2-digit segment is differentiated from the others by a combination of operation mode and timer

Strona 14

VRF-SVX30A-EN 21ConfigurationMode 2: Option SettingWhen digit 2 is set to a value of “2,” the options shown in Table 1 can be set to the values in the

Strona 15 - Insulation

22 VRF-SVX30A-ENConfiguration14 External control0: Disabled1: On/Off control2: Off-only control15 External control output0: Thermostat control1: User

Strona 16 - Wiring the Unit

VRF-SVX30A-EN 23ConfigurationMode 5: Option SettingWhen digit 2 is set to a value of “5,” the options shown in Table 2 can be changed to the values in

Strona 17

24 VRF-SVX30A-ENConfigurationFigure 5. Heat recovery unit operating in auto-changeover mode9Time required for mode changeNote: Applies only when digi

Strona 18 - Configuration

VRF-SVX30A-EN 25ConfigurationMode A: AddressingWhen digit 2 is set to a value of “A,” unit address settings can be changed. See Figure 7, Figure 8, an

Strona 19

26 VRF-SVX30A-ENConfigurationMode d: Specific Digit ChangingWhen digit 2 is set to a value of “d,” a single, specific digit can be changed. See Figur

Strona 20 - Configuration Modes

VRF-SVX30A-EN 27ConfigurationFigure 9. Example of using the specific digit changing mode to change an option settingThe example in Figure 11 shows how

Strona 21 - Mode 2: Option Setting

28 VRF-SVX30A-ENConfigurationTable 4. Specific digit changing mode: Digit 2 = dDisplay screen (Mode and On/Off)DigitOption Set digit to...1 Factory s

Strona 22

VRF-SVX30A-EN 29OperationOperationFamiliarize yourself with the unit components and operating tips before operating the unit.ComponentsNote: Your unit

Strona 23 - Mode 5: Option Setting

Table of ContentsVRF-SVX30A-EN 3Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24

30 VRF-SVX30A-ENOperationInternal ProtectionsInternal protections operate if an internal fault occurs in the unit. Note: If the heat pump is operatin

Strona 25 - Mode A: Addressing

VRF-SVX30A-EN 31Operation2. Hold on to the handle and lift it up. Remove the filter by pulling it towards you.3. Clean the air filter with a vacuum or

Strona 26

32 VRF-SVX30A-ENTroubleshootingTroubleshootingRefer to Table 6 for solutions to common problems and to Table 7 for a list of alarm conditions with co

Strona 27

VRF-SVX30A-EN 33TroubleshootingIf an error occurs, one of more of the LEDs on the display (see “Components” for their location) will flicker. As a pro

Strona 28

34 VRF-SVX30A-ENTroubleshootingCondenser mid-sensor is loose E241On Flickering FlickeringRefrigerant leakage (2nd detection) E554Abnormally high temp

Strona 29 - Operation

VRF-SVX30A-EN 35Warranty For Trane Advantage™ VRF Systems and Related AccessoriesWarranty For Trane Advantage™ VRF Systems and Related AccessoriesProd

Strona 31 - Periodic Maintenance Checks

The manufacturer optimizes the performance of homes and buildings around the world. A business of IngersollRand, the leader in creating and sustaining

Strona 32 - Troubleshooting

4 VRF-SVX30A-ENTroubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Warra

Strona 33

VRF-SVX30A-EN 5Model Number DescriptionDigit 1: RefrigerantDigit 2: Brand name Digit 3: System typeDigit 4: Configuration Type (also see separate tab)

Strona 34

6 VRF-SVX30A-ENPreparing for InstallationPreparing for InstallationAccessoriesIn addition to product literature, the following accessories are suppli

Strona 35 - Related Accessories

VRF-SVX30A-EN 7Preparing for InstallationService Clearances 11.81 in. (300 mm)4.9 in. (125 mm)4.9 in. (125 mm)

Strona 36 - 36 VRF-SVX30A-EN

8 VRF-SVX30A-ENInstallationInstallationReview “Installation Considerations” before proceeding with installation.Follow the procedures in these sectio

Strona 37

VRF-SVX30A-EN 9InstallationPurging the UnitThe unit is shipped from the factory with a holding charge of nitrogen. All of this gas must be purged from